How to Calibrate Your Endress+Hauser pH Meter: A Step-by-Step Guide

Endress+Hauser is a well-known brand in the field of process measurement and automation. Their PH Meters are widely used in various industries to measure the acidity or alkalinity of a solution. Proper calibration of a pH meter is essential to ensure accurate and reliable measurements. In this article, we will provide a step-by-step guide on how to calibrate your Endress+Hauser pH meter.

Before starting the calibration process, it is important to read the user manual provided by Endress+Hauser. The manual contains detailed instructions on how to calibrate the pH meter and should be followed carefully to ensure accurate results. Make sure to have all the necessary equipment and solutions ready before starting the calibration process.

The first step in calibrating your pH meter is to prepare the calibration solutions. Endress+Hauser pH meters typically require two calibration solutions: a pH 4.01 buffer solution and a pH 7.00 buffer solution. These solutions can be purchased from Endress+Hauser or other suppliers of laboratory equipment.

Once you have prepared the calibration solutions, it is time to start the calibration process. Turn on the pH meter and allow it to warm up for a few minutes. Place the electrode of the pH meter into the pH 7.00 buffer solution and wait for the reading to stabilize. Adjust the pH meter if necessary to ensure that it reads the correct pH value.

After calibrating the pH meter with the pH 7.00 buffer solution, rinse the electrode with deionized water and place it into the pH 4.01 buffer solution. Again, wait for the reading to stabilize and adjust the pH meter if needed. Once the pH meter is calibrated with both the pH 4.01 and pH 7.00 buffer solutions, it is ready for use.

It is important to note that pH meters should be calibrated regularly to ensure accurate measurements. Endress+Hauser recommends calibrating their pH meters at least once a month or whenever the electrode is replaced. Regular calibration will help maintain the accuracy and reliability of the pH meter.

In addition to calibration, proper maintenance of the pH meter is also important. Make sure to clean the electrode regularly with a soft brush and rinse it with deionized water after each use. Store the pH meter in a clean and dry place when not in use to prevent damage to the electrode.

Instrument model FET-8920
Measurement range Instantaneous flow (0~2000)m3/h
Accumulative flow (0~99999999)m3
Flow rate (0.5~5)m/s
Resolution 0.001m3/h
Accuracy level Less than 2.5% RS or 0.025m/s.whichever is the largest
Conductivity >20\\u03bcS/cm
(4~20)mA output Number of channels Single channel
Technical features Isolated,reversible,adjustable, meter/transmission\\u00a0dual mode
Loop resistance 400\\u03a9\\uff08Max\\uff09, DC 24V
Transmission accuracy \\u00b10.1mA
Control output Number of channels Single channel
Electrical contact Semiconductor photoelectric relay
Load capacity 50mA\\uff08Max\\uff09, DC 30V
Control mode Instantaneous amount upper/lower limit alarm
Digital output RS485(MODBUS protocol ),Impulse output1KHz
Working power Power supply DC 9~28V
source Power Consumption \\u22643.0W
\\u3000 Diameter DN40~DN300(can be customized)
Working Environment Temperature:(0~50)\\u00a0\\u2103; Relative humidity:\\u00a0\\u226485%RH(none condensation)
Storage environment Temperature:(-20~60)\\u00a0\\u2103; Relative humidity:\\u00a0\\u226485%RH(none condensation)
Protection grade IP65
Installation method Insertion\\u00a0pipeline\\u00a0installation

In conclusion, calibrating your Endress+Hauser pH meter is a simple process that can be done following the instructions provided in the user manual. Regular calibration and maintenance of the pH meter are essential to ensure accurate and reliable measurements. By following the steps outlined in this article, you can ensure that your pH meter performs optimally and provides accurate results for your applications.